JOHOB supplies jockey pump and control panel packages for NFPA 20 fire protection systems nationwide in the Philippines. UL and FM listing is not part of the standard package: it is a buyer-specified requirement we source against at RFQ stage. Standard documentation includes ISO 9001 quality management certification, TUV SUD test reports, and CE marking, with delivery in 21 to 35 days ex-stock or 45 to 90 days made-to-order.

What a Jockey Pump Does in an NFPA 20 Fire Protection System

A jockey pump is a small-capacity, high-pressure pump that maintains constant pressure in a fire sprinkler or standpipe system's piping network between activations of the main fire pump. It cycles on and off automatically to compensate for minor pressure drops caused by small leaks or thermal expansion, so the system does not falsely trigger the much larger main fire pump for every minor fluctuation. In an NFPA 20 compliant fire protection system, the jockey pump is a required component alongside the main pump and the fire reserve tank. JOHOB supplies jockey pump and control panel packages as part of its Fire Protection product category, sized against the specific pressure setpoint and reserve capacity of the buyer's fire protection design. Packages are sourced through an ISO 9001 certified partner factory and delivered with local after-sales support, with JOHOB responding to RFQs within 1 business day. Coverage is nationwide: NCR, Luzon, Visayas, Mindanao, and PEZA / SBMA / Clark zones. Because jockey pump selection depends on the fire protection engineer's hydraulic calculations rather than a fixed catalog size, JOHOB works from the buyer's pressure setpoint and system drawings to confirm the correct pump and control panel combination before quoting.

UL and FM Listing: What It Means for Your RFQ

UL (Underwriters Laboratories) and FM (FM Global) listing are third-party certification marks sometimes specified on fire protection equipment by project specifications, insurance underwriters, or fire protection engineers. UL and FM listing are not part of JOHOB's standard jockey pump package. If your project requires UL or FM listed equipment, flag this at the RFQ stage so JOHOB can source against that specific requirement rather than assume it as a default inclusion. What is included as standard: equipment sourced through an ISO 9001 certified partner factory, with TUV SUD test reports and CE marking documentation supplied as part of the standard package. These three certifications cover the manufacturer's quality management system (ISO 9001), independent testing (TUV SUD), and conformity with applicable European safety directives (CE), and apply broadly across JOHOB's pumping and electrical panel equipment, not only jockey pumps. Buyers working on insurance-driven or project specifications that explicitly call out UL or FM listing should raise this requirement in writing when requesting a quote. JOHOB will confirm whether the specific pump and panel combination required can be sourced to that listing before the quote is issued, since UL/FM sourcing can affect both lead time and pricing versus the standard ISO 9001 / TUV SUD / CE documented package.

Jockey Pump and Control Panel Options JOHOB Supplies

JOHOB supplies jockey pump packages under its Pumping and Pressure Systems category, paired with electrical control panels from the same category: VFD duplex panels, star-delta panels, and SDE panels, depending on how the fire protection design calls for the pump to start and stop. CDL and CDLF vertical multistage pump configurations are among the options sized against fire protection pressure setpoints, with final selection depending on the flow rate (GPM) and discharge pressure (PSI) specified by the buyer's fire protection engineer. Because jockey pump duty is intermittent and pressure-critical rather than continuous-flow, the control panel pairing matters as much as the pump itself: a duplex controller arrangement allows for a lead/lag or alternating setup where the project's fire protection design calls for it. JOHOB quotes the pump and panel as a package rather than as separate line items, so the buyer receives one coordinated RFQ response covering both components, verified against the project's pressure and capacity requirements before quoting. All equipment ships with the certifications described above (ISO 9001, TUV SUD, CE) as standard, with UL/FM sourcing available only when specified in advance. Response to RFQs is within 1 business day, and standard lead times are 21 to 35 days ex-stock or 45 to 90 days for made-to-order configurations.

Certifications and Documentation Supplied With the Equipment

Every jockey pump and control panel package JOHOB quotes ships with three standard certification documents: ISO 9001 certification covering the manufacturer's quality management system, TUV SUD independent test reports, and CE marking documentation confirming conformity with applicable European equipment directives. These documents are supplied with the equipment at delivery and can be requested in advance of PO for buyers who need to submit them as part of a project specification package or insurance underwriting file. UL and FM listing sit outside this standard documentation set. If a buyer's specification, underwriter, or fire protection engineer requires UL or FM listed equipment specifically, this needs to be stated at RFQ stage, since it is a sourcing requirement JOHOB fulfills against the specific request rather than a certification carried by every unit in stock. For buyers operating inside PEZA, SBMA, or other export-processing zones, standard commercial terms apply: 12% VAT for VAT-registered buyers, zero-VAT treatment for PEZA / SBMA locators and exporters. Documentation requests and VAT treatment questions can be raised in the same RFQ as the technical specification, and JOHOB responds within 1 business day.

Sizing the Jockey Pump Against Your Main Fire Pump

A jockey pump must be sized well below the capacity of the main fire pump: its job is to maintain pressure between main pump cycles, not to supply firefighting flow. Correct sizing depends on the pressure setpoint and reserve capacity defined in the project's fire protection engineering drawings, specifically the system's normal operating pressure, the pressure drop that should trigger the jockey pump rather than the main pump, and the piping network's volume. JOHOB sizes jockey pump and control panel packages against the buyer's supplied pressure setpoint and system drawings rather than offering a single fixed-size default. Buyers requesting a quote should include the fire protection engineer's specified flow rate (GPM) and discharge pressure (PSI) for the jockey pump duty point, along with the main fire pump's rated capacity, so the package quoted matches the actual system design rather than a generic selection. Because this sizing step depends on project-specific hydraulic calculations, JOHOB treats it as part of the RFQ review rather than something a buyer should determine alone from a catalog page. RFQs are reviewed and responded to within 1 business day, with standard lead times of 21 to 35 days ex-stock or 45 to 90 days for made-to-order pump and panel combinations.

Lead Times, VAT Treatment, and Nationwide Delivery

JOHOB's standard lead times for jockey pump and control panel packages are 21 to 35 days ex-stock for in-stock configurations, or 45 to 90 days for made-to-order pump and panel combinations that require specific sizing or UL/FM sourcing. RFQs receive a response within 1 business day, so buyers working against a project schedule can confirm lead time against their fire protection system's commissioning date early. Delivery coverage is nationwide across the Philippines: NCR, Luzon, Visayas, and Mindanao, including PEZA, SBMA, and Clark economic zones. Standard commercial terms apply 12% VAT for VAT-registered buyers, with zero-VAT treatment available for PEZA / SBMA locators and exporters. Pricing is quote-based and not published publicly, since jockey pump and control panel packages are sized against project-specific requirements rather than sold as a fixed-price catalog item. Buyers should submit the fire protection engineer's pressure setpoint, required flow rate, and any UL/FM listing requirement together in a single RFQ so JOHOB can confirm sourcing, certification documentation, and lead time in one response rather than multiple rounds of clarification.

Frequently Asked Questions

1

Is JOHOB's jockey pump UL listed?

UL and FM listing are not part of JOHOB's standard jockey pump package. Standard documentation includes ISO 9001 certification covering the manufacturer's quality management system, TUV SUD test reports, and CE marking. If your project specification, insurer, or fire protection engineer requires UL or FM listed equipment, state this at RFQ stage so JOHOB can confirm sourcing against that specific requirement, since it can affect both lead time and pricing compared to the standard documented package.

2

What is the difference between a jockey pump and a main fire pump?

A main fire pump supplies the high flow rate needed to fight an actual fire, sized to the sprinkler or standpipe system's design flow and pressure. A jockey pump is a much smaller pump that runs intermittently to maintain pressure in the piping network between main pump activations, compensating for minor leaks or thermal pressure changes so the main pump does not cycle unnecessarily. Both are required components of an NFPA 20 compliant fire protection system, and JOHOB supplies jockey pump and control panel packages sized against the main pump's rated capacity.

3

How do I know what size jockey pump I need?

Jockey pump sizing depends on your fire protection engineer's hydraulic calculations, not a fixed catalog size. Submit the system's pressure setpoint, the required flow rate (GPM) and discharge pressure (PSI) for the jockey pump duty point, and your main fire pump's rated capacity in your RFQ. JOHOB reviews this against the project's piping network and confirms the correct pump and control panel combination before quoting, responding within 1 business day.

4

What is the lead time and VAT treatment on a jockey pump package?

Standard lead time for jockey pump and control panel packages is 21 to 35 days ex-stock for in-stock configurations, or 45 to 90 days for made-to-order combinations, including configurations that require UL/FM sourcing or non-standard panel builds. VAT-registered buyers are charged 12% VAT on the invoice; PEZA and SBMA locators and exporters qualify for zero-VAT treatment. JOHOB responds to RFQs within 1 business day, so you can confirm lead time against your project's commissioning schedule early.

5

Does JOHOB deliver jockey pump packages outside Metro Manila?

Yes. JOHOB delivers jockey pump and control panel packages nationwide across the Philippines, covering NCR, Luzon, Visayas, Mindanao, and PEZA, SBMA, and Clark economic zones. Pricing is quote-based rather than published, since each package is sized against the buyer's specific fire protection design, and delivery timelines follow the same standard lead times (21 to 35 days ex-stock, 45 to 90 days made-to-order) regardless of destination within the Philippines.

Found this useful? Add Johob as a Preferred Source on Google so our supply guides show up first next time you search.

Talk to Us About Your Project

Send us your requirements and we'll return a written recommendation within 3 to 5 business days. Response within 1 business day.

Request a Quote

sales@johob.com · +63 997 078 9953 (Viber)