Jockey pump CDL 2-11: 8.8 GPM, 185 PSI, 3 HP, SS304, 380V/60Hz. JOHOB supplies nationwide PH, ISO 9001 partner factory, 21-35 day lead time, quote-based.

JOHOB supplies a jockey pump matching the CDL 2-11 specification: 8.8 GPM, 185 PSI, 3 HP / 2.2kW, 3500 RPM, SS304 wetted parts, 380V/60Hz. This spec is sourced from an ISO 9001 certified partner factory and TUV SUD tested, built to hold fire sprinkler system pressure between main pump cycles. Nationwide PH delivery, 21 to 35 day lead time, quote-based pricing.

Understanding the CDL 2-11 Jockey Pump Specification

CDL 2-11 is a model code used across CDL-series vertical multistage pumps. The exact unit JOHOB supplies against this code is rated 8.8 GPM flow at 185 PSI head pressure, driven by a 3 HP (2.2kW) motor running at 3500 RPM. Wetted parts are SS304 stainless steel, and the motor runs on 380V, 60Hz three-phase power, matching standard Philippine industrial electrical supply. These numbers matter for a jockey pump because its job is narrow: hold a fire protection system at setpoint pressure between cycles of the main fire pump, using small, frequent bursts rather than continuous high-volume flow. A jockey pump sized too small cycles too often and wears out early. One sized too large can mask small leaks instead of flagging them for repair. If your spec sheet lists CDL 2-11 at this exact flow and head, JOHOB can match it unit for unit, including the SS304 material call-out, which matters for fire protection piping exposed to stagnant water between demand events. Confirm your required flow, head, voltage, and frequency against this spec sheet before requesting a quote, since local electrical supply in some PH industrial zones varies from standard utility service.

Sourcing, Certification, and Lead Times

This jockey pump spec is sourced from an ISO 9001 certified partner factory and is TUV SUD tested, with CE marking applying where the relevant directive covers the electrical components. JOHOB does not manufacture the pump itself, it sources and supplies the unit, then backs it with local warranty and after-sales support in the Philippines. Standard lead time for this spec is 21 to 35 days if the configuration is held ex-stock, or 45 to 90 days if the unit must be made to order, for example a non-standard voltage or impeller stage count. JOHOB responds to RFQs within 1 business day, confirming which lead time band applies to your exact configuration. Pricing is quote-based, JOHOB does not publish unit prices for this spec. 12% VAT applies for VAT-registered buyers. Buyers operating as PEZA or SBMA locators, or as exporters, qualify for zero-VAT treatment on the purchase, subject to the usual documentation. JOHOB supplies nationwide across NCR, Luzon, Visayas, and Mindanao, including PEZA, SBMA, and Clark zones, so a single RFQ can cover delivery to any of these locations without a separate sourcing process per site.

Pairing This Jockey Pump with a Duplex VFD Controller

A jockey pump rarely runs alone in a fire protection system, and this CDL 2-11 unit is no exception. JOHOB supplies duplex VFD control panels, built around Inovance drives, that pair with this exact pump spec to manage start and stop cycling without the pressure spikes that wear down mechanical seals over time. A duplex configuration also gives the system a second pump path if the primary jockey pump needs servicing, which matters for a system that is required to hold pressure continuously, not just during a fire event. See the dedicated duplex VFD jockey pump controller page for panel specifications and how the controller logic is configured against this pump's 185 PSI setpoint and 3500 RPM motor speed. If you are specifying both the pump and the panel in one RFQ, note the pairing on your request so JOHOB quotes them as a matched set rather than two separate line items, which simplifies the lead time calculation and keeps both components aligned to the same electrical supply, 380V at 60Hz.

Where This Jockey Pump Fits in a Fire Protection System

A jockey pump's function in a fire protection system is to make up small pressure losses from minor leaks or thermal contraction, keeping the system at setpoint so the much larger main fire pump does not start for anything short of a real demand event. JOHOB's fire protection category also covers fire reserve tanks and sprinkler kits, so a jockey pump of this spec is typically part of a larger package rather than a standalone purchase. Philippine fire protection design commonly calls for this pressure-maintenance function on sprinkler systems in commercial and institutional buildings, which is where this CDL 2-11 spec, rated to 185 PSI, is most often applied. If your building's fire protection engineer has specified UL or FM listing requirements for any component in the system, flag that at RFQ stage. UL and FM listing is a buyer-specified requirement to verify per component, not a blanket certification JOHOB applies across its fire protection equipment line. Confirming this early avoids a mismatch between what is quoted and what your fire code reviewer will accept at inspection.

How to Request a Quote for This Spec

To request a quote for this jockey pump spec, submit an RFQ with the full nameplate detail: CDL 2-11, 8.8 GPM, 185 PSI, 3 HP (2.2kW), 3500 RPM, SS304, 380V/60Hz. JOHOB responds within 1 business day with a quote-based price, the applicable lead time band (21 to 35 days ex-stock or 45 to 90 days made-to-order), and confirmation of VAT treatment based on whether your business is VAT-registered or a PEZA/SBMA locator or exporter. If you need this pump paired with a duplex VFD control panel, or with a fire reserve tank and sprinkler kit as part of a larger fire protection package, say so in the same RFQ so JOHOB can quote the full scope together rather than piecemeal. JOHOB does not publish unit prices publicly for this spec, every quote is built against your exact site requirements, so include your intended installation location and any UL or FM listing requirement from your fire protection engineer at the time of request. Delivery is available nationwide across NCR, Luzon, Visayas, Mindanao, and PEZA/SBMA/Clark zones.

Frequently Asked Questions

1

What does the CDL 2-11 designation mean for a jockey pump?

CDL 2-11 is a model code used across CDL-series vertical multistage pumps rather than a JOHOB-exclusive designation. The specific unit JOHOB supplies against this code is rated 8.8 GPM at 185 PSI head, driven by a 3 HP (2.2kW) motor at 3500 RPM, with SS304 wetted parts and a 380V, 60Hz three-phase power requirement. If your fire protection engineer's spec sheet lists CDL 2-11 at these exact numbers, JOHOB can match the configuration directly. Confirm flow, head, voltage, and frequency against your own spec sheet before requesting a quote, since local electrical supply can vary by site.

2

Can JOHOB supply this exact jockey pump spec in the Philippines?

Yes. JOHOB sources and supplies this CDL 2-11 configuration (8.8 GPM, 185 PSI, 3 HP, SS304, 380V/60Hz) nationwide across NCR, Luzon, Visayas, Mindanao, and PEZA/SBMA/Clark zones. The unit comes from an ISO 9001 certified partner factory and is TUV SUD tested, backed by local warranty and after-sales support. Standard lead time is 21 to 35 days if the configuration is held ex-stock, or 45 to 90 days if it must be made to order. JOHOB responds to RFQs within 1 business day to confirm which lead time applies to your request.

3

Does this jockey pump need a separate control panel?

In practice, yes. A jockey pump is normally run with a dedicated control panel that handles start and stop cycling as system pressure drifts around the 185 PSI setpoint. JOHOB supplies duplex VFD control panels built around Inovance drives that pair with this CDL 2-11 spec, giving the system a backup pump path and smoother cycling than a basic pressure switch setup. If you are specifying both the pump and the panel, mention the pairing in your RFQ so JOHOB quotes them together as a matched set rather than as two separate, unaligned line items.

4

Is VAT included in the quoted price?

JOHOB quotes are built per request and VAT treatment depends on your business registration. A 12% VAT applies for standard VAT-registered buyers. Buyers operating as PEZA or SBMA locators, or as exporters, qualify for zero-VAT treatment on the purchase, subject to standard documentation. JOHOB does not publish a public unit price for this spec, since pricing depends on your exact configuration, delivery location, and VAT status. State your registration type in the RFQ so the quote reflects the correct VAT treatment from the first response.

5

How long does delivery take for this jockey pump spec?

Delivery depends on whether the CDL 2-11 configuration you need is held ex-stock or must be made to order. Ex-stock configurations ship in 21 to 35 days. A made-to-order configuration, for example a non-standard voltage or an unusual impeller stage count, takes 45 to 90 days. JOHOB confirms which band applies within 1 business day of receiving your RFQ, along with a quote-based price and VAT treatment. Nationwide delivery is available across NCR, Luzon, Visayas, Mindanao, and PEZA/SBMA/Clark zones.