Industrial cooling tower — evaporative
Cooling tower installation — side view
Cooling tower detail shot

Industrial Cooling Tower

Open-circuit (evaporative) and closed-circuit cooling towers for condenser cooling, process cooling, and HVAC loops. FRP, steel, or concrete construction. 100 TR to 5,000+ TR capacity.

WRAS · ISO 9001 · TÜV · CE · ASME · PED|Nationwide PH delivery|Quote in 3 to 5 business days|1 business day response

CTIEuroventCEISO 9001:2015

Overview

Cooling towers reject waste heat from industrial processes and power generation to the atmosphere via evaporative cooling. Essential pairing for steam condensers, chiller plants, process heat exchangers, and any closed-loop water system that needs to shed heat. Open-circuit (evaporative) towers spray hot water over fill media while fans draw air through — a small fraction evaporates, carrying heat away, cooling the remaining water by 5-15°C. Closed-circuit (fluid cooler) towers keep the process fluid sealed inside coils, spraying external water over them — used for clean-water-sensitive applications. FRP (Fiberglass Reinforced Plastic) construction is standard for corrosion resistance; steel and concrete options available for large capacities. Common applications: power plant condenser cooling, chiller condenser water loops, plastic injection moulding, metal processing, food & beverage, HVAC central plants.

Key Features

Counter-flow or cross-flow airflow designs
FRP (Fiberglass Reinforced Plastic) construction — standard
Galvanized steel or SS304 structural options available
PVC fill media (film-type) or splash-type
Drift eliminators — <0.005% drift loss
Axial or centrifugal fans (depending on capacity)
Direct-drive or belt-drive fan configurations
Variable Frequency Drive (VFD) fan control for energy savings
Open-circuit or closed-circuit (fluid cooler) designs
Modular cells for capacities up to 5,000+ TR

Technical Specifications

Cooling Capacity100 TR (Tons of Refrigeration) to 5,000+ TR
TypeOpen-circuit / Closed-circuit (fluid cooler)
Flow ArrangementCounter-flow or Cross-flow
ConstructionFRP / Galvanized Steel / SS304 / Concrete
Fill MediaPVC film-fill / Splash-type
Approach Temperature3-5°C typical
Cooling Range5-15°C
Fan TypeAxial (large) / Centrifugal (low-noise)
Drift Loss<0.005% of circulating flow
StandardsCTI-ATC-105 / Eurovent certified

Applications

Steam condenser cooling water loops
Chiller plant condenser water (HVAC)
Plastic injection moulding cooling
Metal processing and forging
Food & beverage processing
Data center cooling (hybrid and indirect)
Power plant auxiliary cooling
Commercial laundry process cooling

What Determines Your Quote

Every quote is engineered to your operating requirements. Pricing depends on:

  • Configuration: capacity, flow rate, head pressure, motor size, voltage/phase, materials of construction
  • Certification tier: WRAS-cert vs commercial-grade, ASME stamping, IP rating for panels
  • Delivery region: nationwide (Metro Manila, Luzon, Visayas, Mindanao); freight varies by destination
  • Installation scope: supply-only, supply + mechanical install, or full turn-key with commissioning
  • Payment structure: milestone terms tailored to project timeline (typically 40/30/20/10 for engineered scopes; 70/30 for equipment supply)
  • Tax status: 12% VAT applies to VAT-registered buyers; Zero-VAT available for eligible PEZA / SBMA locators and exporters

Formal written quote within 3 to 5 business days of complete spec confirmation. Response within 1 business day to every inquiry.

Frequently Asked Questions

What certifications come with an industrial cooling tower?

Every industrial cooling tower we supply is built to CTI ATC-105 and Eurovent thermal performance standards, carries CE marking, and comes from an ISO 9001:2015 certified production line, so the thermal duty stated on the datasheet is backed by a recognized rating method rather than a bare catalog claim. Material test certificates for the FRP panels, structural steel, and fill media are included in every shipment, together with the factory inspection report covering fan balancing, drift eliminator fit, and dimensional checks. These documents arrive with the delivery paperwork, which means your procurement, permit, and QA files are complete without chasing anything after the fact. As your industrial supply partner, we also hand over the thermal performance datasheet and fan curve for the specific tower configuration you ordered. If your project requires a specific additional certification, tell us at inquiry stage and we confirm availability in the written quotation.

What is the standard lead time for a cooling tower?

Standard lead time for an industrial cooling tower runs 60 to 120 days from down payment, depending on capacity, construction material, and whether the design is a catalog configuration or an engineered multi-cell arrangement. Smaller single-cell FRP towers sit at the shorter end of that range, while large multi-cell installations in the thousands of TR, or towers with SS304 structure and closed-circuit coils, take longer because of custom fabrication. The exact schedule for your specific configuration is confirmed in the written quotation, which we issue within 3 to 5 business days of receiving your duty requirements. If your project has a hard commissioning date, tell us during inquiry: sequencing the basin civil works and piping in parallel with tower fabrication is the usual way to protect the overall project timeline, and we flag any long-lead items early.

Do you deliver cooling towers to Luzon, Visayas, Mindanao, SBMA, and Clark?

Yes, delivery covers the whole Philippines: Metro Manila, all Luzon provinces, Visayas, and Mindanao, with regular deliveries to SBMA, Clark, and PEZA industrial estates. Cooling towers up to a few hundred TR typically ship as knocked-down modules (casing panels, fill packs, fan assemblies, and structure) that travel well on standard trucking and inter-island freight, while very large multi-cell towers are planned as staged deliveries matched to your erection sequence. For provincial and island sites we coordinate the trucking, shipping, and offloading requirements as part of the quotation, so you see the landed cost to your site rather than a warehouse price plus surprises. If your plant sits inside a locator zone such as SBMA or Clark, tell us during inquiry and we align the delivery documentation with your zone's gate pass and entry procedures.

Is installation included, or is this supply-only?

Both options are available: supply-only or supply-plus-installation, quoted separately so you can compare the numbers and decide what fits your project. Supply-only means the tower ships as documented modules with erection drawings, and your own contractor handles assembly, basin tie-ins, and piping. Supply-plus-install adds our erection team for mechanical assembly, fill and drift eliminator installation, fan alignment, and commissioning support, which is the route most buyers take for multi-cell towers or first-time cooling tower projects. Basin civil works and electrical supply to the fan motors are normally by others in either scope, and we state the exact scope boundary line by line in the written quotation so nothing falls between contractors. Tell us your preferred arrangement at inquiry and we quote both scopes side by side within 3 to 5 business days of your inquiry.

What warranty does a cooling tower carry?

The warranty term for your specific tower configuration is confirmed in the written quotation, because coverage depends on the construction material, fan and drive package, and whether the scope is supply-only or includes installation. What is standard on every unit: the warranty certificate, material test certificates, and factory inspection reports are all included in the delivery documents, so your compliance and maintenance records are complete from day one. Warranty claims run through our team as your single point of contact, meaning you deal with one accountable industrial supply partner rather than tracing responsibility across component makers. Wear-and-consumable items such as fill media fouling from poor water treatment are typically excluded, which is normal across the industry, and we walk you through the exact inclusions and exclusions before you sign. Ask for the warranty annex when you request your quote.

Can you customize a cooling tower to a non-standard specification?

Yes, customization is normal for cooling towers because thermal duty is site-specific. We regularly engineer around non-standard requirements: unusual approach temperatures, low-noise centrifugal fan packages for towers near offices or residences, SS304 structure for corrosive coastal air, closed-circuit coil designs for clean-loop processes, VFD fan control for energy savings, and modular multi-cell arrangements sized to constrained footprints or rooftop structural limits. To quote a custom design we need your heat load or water flow, hot and cold water temperatures, design wet-bulb temperature for your location, and any footprint, height, or noise constraints. Send those parameters and we return a specced quotation with thermal selection and general arrangement drawings within 3 to 5 business days. Custom engineering does extend fabrication time versus a catalog unit, and the exact schedule is confirmed in the written quotation.

Ready to Spec This In?

Send us your requirements (capacity, location, timeline, install scope) and we'll return a fully specced quotation with drawings, material certificates, and lead time within 3 to 5 business days.

Request a Quote

sales@johob.com · +63 997 078 9953 (Viber)

Common inquiries we can answer today: sizing math, alternative product recommendations, delivery estimates, milestone payment structures, PhilGEPS or PEZA compliance paperwork.