Jockey Pump for Fire System Supplier in Manila
CDL/CDLF vertical multistage jockey pumps sized against your fire protection engineer's pressure setpoint, with star-delta or VFD control panels supplied nationwide.
What We Supply for Jockey Pump Duty in Manila
JOHOB Hardware Trading is a Philippines-based industrial equipment supplier serving commercial, industrial, and institutional buyers across Manila and nationwide. A jockey pump is a small pressure maintenance pump inside a fire protection system: it holds the sprinkler and standpipe network at its set pressure between main pump runs, making up minor leaks and thermal contraction so the much larger main fire pump is not started and stopped on trivial demand. Building administrators, fire protection contractors, and MEP consultants come to us for jockey duty because the pump has to be matched to the main fire pump and the pressure setpoint, not bought off a generic catalogue line. We source from Philippine and China factories and deliver with local warranty and after-sales support, so a Manila building is not chasing an overseas factory when a jockey pump needs attention. Pricing is quote-based. Send your system pressure setpoint and the main fire pump's rated duty, and we respond within one business day.
The CDL/CDLF Pump Line We Supply for Jockey Duty
Jockey pump duty is a low-flow, high-head profile, and the vertical multistage design is the right architecture for it, because it holds a steep, stable pressure curve at low flow instead of the flat curve a general-purpose centrifugal pump produces. We supply this role from our CDL/CDLF vertical multistage pump range.
| Specification | Range |
|---|---|
| Flow rate | 1 to 240 m3/hr |
| Head | Up to 300+ metres |
| Power | 0.37kW to 200kW |
| Material | SS304 standard, SS316 on the CDLF variant |
A jockey pump duty point sits at the low-flow end of that range, sized to offset the actual leakage rate of your specific system rather than to a rule of thumb. We quote against the number your fire protection engineer has calculated, not against a generic fraction of the main pump.
Sizing the Jockey Pump Against the Main Fire Pump
A jockey pump quotation moves fastest when it carries three numbers rather than a single flow figure.
- The system pressure setpoint your fire protection engineer has specified for the sprinkler and standpipe network
- The pipe volume being held at pressure, which drives how much leakage the jockey pump has to offset
- The main fire pump's rated flow and pressure, so the jockey duty is scoped against the same system rather than in isolation
Send those three and we will confirm the jockey pump model against your CDL/CDLF duty point. If you do not yet have the pressure setpoint confirmed, send the main fire pump specification and the building type, and we will flag what still needs confirming before we can quote rather than guessing at a number. This is the same discipline we apply on every jockey pump enquiry, because a pump sized against a guessed setpoint is a pump that either short cycles against real leakage or fails to hold pressure when the system actually needs it.
Control Panels for Jockey Pump Duty
Jockey pumps typically run on a pressure-switch or star-delta starter rather than a VFD, because the duty is start-stop pressure maintenance rather than continuous flow modulation. We supply star-delta, soft-start, and VFD panels built by Chutian using Inovance drives, and we will confirm which control type fits your fire protection engineer's design before quoting. If your fire pump controller assembly is specified as a listed fire service assembly, tell us at RFQ stage and we confirm in writing what listing documentation the factory can provide for the exact model proposed. We do not make blanket listing claims across our equipment range, because listing applies to specific models, not to a supplier.
Certification and Documentation Supplied With the Equipment
Equipment we supply carries ISO 9001 manufacturer quality management certification, TUV SUD testing, and CE marking on the electrical scope. Pressure vessels carry ASME certification where applicable. JOHOB Hardware Trading is a supplier, not a licensed installer, and is not PCAB accredited, so installation and the fire protection acceptance test in front of the Authority Having Jurisdiction stay with your appointed fire protection contractor. Ask for the specific certificates covering your jockey pump and panel at quotation stage rather than after delivery, so the document pack is ready for your submittal without a follow-up request.
Lead Times, VAT Treatment, and Delivery Into Manila and Nationwide
Standard lead times are 21 to 35 days for ex-stock configurations and 45 to 90 days for made-to-order equipment. A jockey pump matched to a specific duty point and paired with a built-to-order panel usually falls in the made-to-order band, so raise your commissioning date at RFQ stage and we will confirm which band applies rather than quoting an optimistic number. On tax, 12 percent VAT applies to VAT-registered buyers. Zero-VAT treatment applies to PEZA and SBMA locators and to registered exporters, so state your registration status when you send the RFQ and the quotation carries the correct treatment from the start. We deliver nationwide: NCR, the rest of Luzon, Visayas, and Mindanao, including PEZA, SBMA, and Clark locators. Pricing is quote-based and we do not publish prices, since the jockey pump and panel figure depends on the duty point and the control specification. We respond to RFQs within one business day.
Frequently Asked Questions
What does a jockey pump do in a fire protection system?
A jockey pump is a small pressure maintenance pump that holds the fire sprinkler and standpipe system at its set pressure between main pump runs. It makes up minor pressure losses from small leaks and thermal contraction so the much larger main fire pump does not start and stop on trivial demand. Without a jockey pump, the main pump short cycles every time system pressure drifts down, which wears the driver and the controller far faster than the duty was ever meant to see.
What size jockey pump do I need for my building?
Jockey pump sizing is a low-flow, high-head duty, typically a small fraction of the main fire pump's rated flow, just enough to offset normal system leakage and hold setpoint. Send your fire protection engineer's system pressure setpoint, the pipe volume being held, and the main fire pump's rated flow and pressure, and we will size the jockey pump against that duty point rather than against the main pump alone. Our CDL/CDLF vertical multistage range covers 1 to 240 cubic metres per hour and heads up to 300plus metres, which spans the great majority of jockey duty points on Philippine commercial and institutional buildings.
Which pump line do you supply for jockey duty?
We supply the jockey pump role from our CDL/CDLF vertical multistage pump line: SS304 stainless steel wetted parts as standard, with an SS316 option on the CDLF variant, flow from 1 to 240 cubic metres per hour, head up to 300plus metres, and power from 0.37kW to 200kW. The vertical multistage design suits jockey duty because it holds a steep, stable pressure curve at low flow, which is exactly the behaviour a pressure maintenance pump needs.
Do you supply the jockey pump controller, or just the pump?
Both. Jockey pumps are typically run on a simple pressure-switch or star-delta starter rather than a VFD, since the duty is start-stop pressure maintenance rather than continuous modulation. We supply star-delta, soft-start, and VFD panels built by Chutian with Inovance drives, and we will confirm which control type fits your fire protection engineer's design before quoting. If your fire pump controller assembly is a listed fire service assembly, tell us at RFQ stage and we confirm what listing documentation the factory can provide for the specific model.
Do you deliver to Manila and nationwide, and how is VAT handled?
Yes. We deliver nationwide across the Philippines, covering NCR, the rest of Luzon, Visayas, and Mindanao, including PEZA, SBMA, and Clark locators. Standard lead times are 21 to 35 days for ex-stock configurations and 45 to 90 days for made-to-order equipment. On tax, 12 percent VAT applies to VAT-registered buyers, while PEZA and SBMA locators and registered exporters are treated as zero-VAT. We respond to RFQs within one business day.
What certifications and documentation come with the jockey pump?
Equipment we supply carries ISO 9001 manufacturer quality management certification, TUV SUD testing, and CE marking on the electrical scope. Pressure vessels carry ASME certification where applicable. JOHOB Hardware Trading is a supplier, not a licensed installer, and is not PCAB accredited, so installation and the fire protection acceptance test stay with your appointed fire protection contractor. Ask for the specific certificates covering your jockey pump and panel at quotation stage rather than after delivery.
Related Pages
- Fire Protection Equipment
- Hydrant Pump Package Supplier Philippines
- Fire Pump Supplier Philippines: NFPA 20 Guide
- Vertical Multistage Pump, CDL/CDLF Series
Reviewed: August 2026