JOHOB Hardware Trading is a Philippines-based supplier of constant pressure water systems, packaged as vertical multistage pumps, VFD duplex control panels, hydropneumatic pressure tanks and piping accessories on one quotation. We deliver nationwide across NCR, Luzon, Visayas, Mindanao and PEZA, SBMA and Clark zones, with local warranty and after-sales support. Lead times run 21 to 35 days ex-stock or 45 to 90 days made-to-order, and we respond to RFQs within 1 business day.
What a Constant Pressure Water System Is and How It Works
A constant pressure water system holds water pressure steady at every outlet in a building, regardless of how many taps, showers or process lines are drawing at the same time. In a Philippine commercial building fed from a ground cistern or roof tank, gravity alone rarely delivers usable pressure to upper floors, and a single fixed-speed pump cycles hard, wastes energy and produces the pressure swings occupants complain about. A constant pressure package solves this by pairing a vertical multistage pump set with a variable frequency drive that modulates motor speed against a pressure transducer. When demand rises, pump speed rises. When demand falls, speed falls, and a hydropneumatic tank absorbs small draws so the pump does not restart for a single handwash. JOHOB Hardware Trading supplies these as a complete package rather than as loose parts, so one supplier is accountable for the pump, the panel, the tank and the connecting accessories. That accountability matters at commissioning, because a pressure complaint in a mixed-supplier install usually turns into a dispute over whose component is at fault while the building owner waits. Everything we supply carries local warranty and after-sales support in the Philippines, and we quote the package on a single line-itemised document with the lead time band and the VAT treatment stated up front rather than discovered later.
The Four Components in a JOHOB Constant Pressure Package
A JOHOB constant pressure package is built from four supplied groups, all quoted on one document. Vertical multistage pumps are the pressure-generating element, selected as duplex or triplex sets so a standby unit is always available and duty alternates between pumps to equalise running hours. Multistage construction produces the head a mid-rise or high-rise riser needs without the oversized motor a single-stage pump would require for the same duty point. VFD duplex control panels are where constant pressure actually happens. The panel reads a pressure transducer on the discharge manifold and drives the pumps to hold a setpoint, with duty and standby alternation, dry-run protection and fault indication. Where a project specification calls for fixed-speed control instead, we supply star-delta, soft starter and MCC panels, and our guide on VFD versus fixed-speed pumps works through the selection tradeoff. Hydropneumatic pressure tanks buffer small draws and short cycles so the pump set is not started for every minor demand, which is what protects motor and contactor life over the years. Piping, fittings and accessories complete the scope: stainless steel flexible hoses, ball valves and gate valves, so the manifold arrives as an assembly rather than as a parts list your contractor has to source separately. Buyers starting from an empty pump room usually take the complete constant pressure booster pump package. Where the project also needs storage, the tank scope is supplied under our sister brand TankSmith as FRP, GRP, hot dip galvanised or stainless modular tanks. Fire reserve tanks and sprinkler kits are available where the same pump room carries a fire protection duty.
Sizing a Constant Pressure System for a Philippine Building
Sizing a constant pressure system comes down to two numbers: the flow the building actually draws at peak, and the pressure that flow has to be delivered at, measured at the highest and furthest outlet. Get either wrong and the result is either a pump that short cycles itself to an early failure or a system that cannot hold pressure on the top floor at 6am. To quote accurately we ask for the number of storeys and the height from pump room to highest fixture, the fixture count or fixture unit schedule, the facility type and its usage pattern, the source of supply (ground cistern, deep well, roof tank or utility main), riser pipe size and material, and the available electrical supply at the pump room. Facility type changes the answer more than most buyers expect. A hotel with simultaneous morning shower demand, a commercial laundry with heavy intermittent draw, a hospital with continuous critical duty and a food processing plant with washdown cycles produce four very different demand curves from the same floor area, and a package sized for one of them will underperform for another. We publish the underlying method in our buying guides rather than keeping it behind a sales call, including booster pump sizing for commercial buildings, VFD versus fixed-speed selection and worked examples for 15 storey and 20 storey buildings. Send the inputs above and we respond within 1 business day.
Certifications and Documentation Supplied With Every System
Every constant pressure package ships with the documentation a Philippine project engineer, building official or third-party inspector will ask for, and we send it as a complete set rather than one certificate at a time.
| Certification | Applies to |
|---|---|
| ISO 9001 | Partner factory quality management systems |
| TUV SUD testing | Equipment in our supplied range, per line |
| CE marking | Electrical scope, including VFD and control panels |
| ASME | Pressure vessels, where the application calls for it |
| WRAS | Potable water tank panels, not pumps or drives |
WRAS certification covers panels in contact with drinking water, which is the specific document a hospital, hotel or food facility will want on file before acceptance. Alongside the certificates we supply the practical documents that get a system accepted and maintained: pump curves with the duty point marked, panel schematic and wiring diagram, motor and drive datasheets, and warranty terms in writing. If your consultant requires a particular submittal format, tell us at RFQ stage and we will match it rather than sending a generic pack that comes back for revision. JOHOB Hardware Trading is an equipment supplier. We source from vetted overseas manufacturers and Philippine partners, and we back the delivered equipment with local warranty and after-sales support in the Philippines, so a defect claim is handled here rather than routed to a distant factory.
Lead Times, VAT Treatment, and How Quotation Works
Pricing is quote based. We do not publish prices for constant pressure packages, because the pump duty point, panel rating, tank volume and accessory scope change the figure substantially between two buildings of the same floor area, and a published number would mislead more buyers than it would help. Lead times fall into two bands. Ex-stock configurations run 21 to 35 days. Made-to-order builds, where the pump duty, panel rating or tank configuration is specific to the project, run 45 to 90 days. We state which band applies on the quotation itself, so the figure can go straight into a construction programme without a follow-up call. VAT treatment is set at quotation stage: 12% VAT applies to VAT-registered buyers, and zero-VAT applies to PEZA and SBMA locators and to exporters. We prepare the document in the correct treatment from the start rather than reissuing it after your finance team flags it, which is a routine delay when a supplier has only ever invoiced ordinary domestic buyers. RFQ response is within 1 business day. Send the sizing inputs listed above, or send your consultant’s equipment schedule and we will price directly against it. If the schedule specifies something we do not supply, we will say so plainly rather than substituting quietly and letting it surface at delivery.
Delivery Coverage and Facility Types We Supply
We deliver nationwide in the Philippines: NCR, the rest of Luzon, Visayas and Mindanao, including PEZA zones, SBMA and Clark. Economic zone deliveries are handled with the zero-VAT documentation locators need, which is a recurring friction point when a supplier has only ever invoiced ordinary domestic buyers and has to learn the paperwork on your project. Facility types we build constant pressure packages for include hotels and resorts, hospitals, dialysis centres and other medical facilities, commercial laundries, food and beverage processing plants, condominiums and mid-rise to high-rise residential towers, and industrial plants inside economic zones. Each of these has a dedicated page on this site covering the sizing considerations specific to that facility type, because the demand curve, not the building size, is what drives selection. Beyond the pressure package itself, JOHOB Hardware Trading supplies the adjacent scope most of these projects also need: water storage through our sister brand TankSmith, covering FRP modular water tank supply along with GRP, hot dip galvanised and stainless tanks; electrical panels including VFD, star-delta and MCC; steam and boiler systems with condensate return; piping and valve accessories; and fire protection including fire reserve tanks and sprinkler kits. Buying the pressure system and its neighbouring scope from one supplier removes the interface risk between them and keeps one warranty contact for the whole package.
Frequently Asked Questions
How much does a constant pressure water system cost in the Philippines?
Pricing is quote based and we do not publish figures, because the pump duty point, panel rating, hydropneumatic tank volume and accessory scope change the total substantially between two buildings of similar size. Send your storey count, height to the highest fixture, fixture schedule and facility type, and we return a line-itemised quotation within 1 business day. The quotation states the lead time band (21 to 35 days ex-stock, or 45 to 90 days made-to-order) and the correct VAT treatment: 12% for VAT-registered buyers, zero-VAT for PEZA and SBMA locators and exporters.
What is the lead time for a constant pressure water system in the Philippines?
There are two bands. Ex-stock configurations ship in 21 to 35 days. Made-to-order builds, where the pump duty, panel rating or tank configuration is specific to your project, run 45 to 90 days. We state which band applies on the quotation itself so it can go directly into your construction programme. If your schedule is tight, give us the required on-site date at RFQ stage and we will tell you honestly whether an ex-stock configuration can meet it, rather than committing to a date we cannot hold.
Do you supply PEZA and SBMA locators, and how is VAT handled?
Yes. We deliver nationwide including PEZA zones, SBMA and Clark. Zero-VAT treatment applies to PEZA and SBMA locators and to exporters, while 12% VAT applies to VAT-registered domestic buyers. We prepare the quotation in the correct treatment from the start rather than issuing a VAT-inclusive document that your finance team then has to send back for reissue. Provide your registration details with the RFQ so the paperwork is correct on the first pass and delivery into the zone is not held at the gate.
What is included in a constant pressure package, and what do I source myself?
Four groups, quoted on one document: vertical multistage pumps in duplex or triplex configuration, a VFD duplex control panel with duty and standby alternation and dry-run protection, a hydropneumatic pressure tank, and piping accessories including stainless steel flexible hoses, ball valves and gate valves. Water storage, where the project needs it, is supplied under our sister brand TankSmith as FRP, GRP, hot dip galvanised or stainless modular tanks. Installation and site works sit outside the supplied equipment scope unless quoted separately, so confirm that at RFQ stage.
What certifications come with the equipment you supply?
The equipment is produced under ISO 9001 certified partner factory quality management systems and is TUV SUD tested. Electrical scope, including VFD and control panels, carries CE marking. Pressure vessels carry ASME certification where the application requires it. Where the package includes potable water storage, tank panels are WRAS certified for contact with drinking water. We send the certificate set together with pump curves, panel schematics and equipment datasheets rather than one document at a time. If your consultant needs a particular submittal format, say so at RFQ stage.
Why use a VFD instead of a fixed-speed pump for constant pressure?
A fixed-speed pump runs at one speed and controls pressure by starting and stopping, which produces the pressure swings occupants notice and the frequent starts that shorten motor and contactor life. A VFD modulates pump speed against a pressure transducer to hold a setpoint, so pressure stays steady from a single tap through to full building demand. We supply both. Where a project specification calls for fixed-speed control, we supply star-delta, soft starter or MCC panels instead. Our VFD versus fixed-speed guide covers the selection tradeoff in detail.
Related Pages
- Complete Booster Pump System
- VFD Duplex Control Panel
- Commercial Water Pressure Boosting Systems
- Variable Speed Booster Pump Quotation, Manila
- Guide: How to Size a Booster Pump
Reviewed: August 2026
Talk to Us About Your Project
Send us your requirements and we'll return a written recommendation within 3 to 5 business days. Response within 1 business day.
Request a Quotesales@johob.com · +63 997 078 9953 (Viber)